CHX – 100 Series
Replaceable 5/8″ diameter Hi-Density Cartridge Heater Cast Aluminum heat exchanger body Operating pressure up to 3200 PSI Operating temperature up to 650°F (343°C) Heater Lengths: 6.5″ and 12.5″
CHX – 100 Series
Replaceable 5/8″ diameter Hi-Density Cartridge Heater Cast Aluminum heat exchanger body Operating pressure up to 3200 PSI Operating temperature up to 650°F (343°C) Heater Lengths: 6.5″ and 12.5″
Optional Design Features:
- Process Thermocouple
- Overtemperature Thermocouple
- High Limit Thermostat
- Incoloy Tubing
- Cast Bronze Heat Exchanger Body
- Operating pressure up to 1400 psi @ 1200°F (649°C)
| Length L |
Inlet-to-Outlet Centerline “A” | Mounting Holes “B” | Flow Tube OD | Flow Tube Material | Used with Insulation Blanket |
|---|---|---|---|---|---|
| 6.5 | 5.75 | 4.75 | 1/4 | 316 SS | BLK50001 |
| 12.5 | 11.75 | 10.75 | Seamless | BLK50002 |
Scroll for more
CHX – 200 Series
Cast-In Tubular Heater Cast Aluminum heat exchanger body Operating pressure up to 3000 PSI Operating temperature up to 650°F (343°C) Heater Lengths: 13.5″, 19.5″, and 23.75″ Single- or Three-Phase
CHX – 200 Series
Cast-In Tubular Heater Cast Aluminum heat exchanger body Operating pressure up to 3000 PSI Operating temperature up to 650°F (343°C) Heater Lengths: 13.5″, 19.5″, and 23.75″ Single- or Three-Phase
Optional Design Features:
- Process Thermocouple
- Overtemperature Thermocouple
- Type MPR (Moisture Resistant) or Type EP (Explosion Resistant) Housings
- Incoloy Tubing
- Cast Bronze Heat Exchanger Body
- Operating pressure up to 1400 psi @ 1200°F (649°C)
| Length L | Inlet-to-Outlet Centerline “A” | Mounting Holes “B” | Flow Tube OD | Flow Tube Material | Used with Insulation Blanket |
|---|---|---|---|---|---|
| 13.5 | 11.75 | 10 | 316 SS | BLK50003 | |
| 19.5 | 17.75 | 16 | 1/2 | Seamless | BLK50004 |
| 25.5 | 23.75 | 22 | BLK50005 |
Scroll for more
CHX – 300 Series
Cast-In Tubular Heater Cast Aluminum heat exchanger body Operating pressure up to 2600 PSI Operating temperature up to 650°F (343°C) Heater Lengths: 13.5″, 19.5″, and 25.5″ Single- or Three-Phase
CHX – 300 Series
Cast-In Tubular Heater Cast Aluminum heat exchanger body Operating pressure up to 2600 PSI Operating temperature up to 650°F (343°C) Heater Lengths: 13.5″, 19.5″, and 25.5″ Single- or Three-Phase
Optional Design Features:
- Process Thermocouple
- Overtemperature Thermocouple
- Type MPR (Moisture Resistant) or Type EP (Explosion Resistant) Housings
- Incoloy Tubing
- Cast Bronze Heat Exchanger Body
- Operating pressure up to 1400 psi @ 1200°F (649°C)
| LengthL | Inlet-to-OutletCenterline “A” | Mounting Holes “B” | FlowTube OD | Flow TubeMaterial | Used withInsulation Blanket |
|---|---|---|---|---|---|
| 13.5 | 11.75 | 10 | 316 SS | BLK50006 | |
| 19.5 | 17.75 | 16 | 3/4 | Seamless | BLK50007 |
| 25.5 | 23.75 | 22 | BLK50008 |
Scroll for more
Electrical Terminations
No options available for this section based on your selections
Type CN: NPT Fitting
A double threaded pipe fitting is attached to the end of a cartridge heater to allow for installation into a threaded hole. Brass fittings are silver brazed and stainless steel fittings are heli-arc welded.
Type CN: NPT Fitting
A double threaded pipe fitting is attached to the end of a cartridge heater to allow for installation into a threaded hole. Brass fittings are silver brazed and stainless steel fittings are heli-arc welded.
Type T: Mica Insulator
Mica insulator is the same diameter as the heating element. .260″ diameter heater has 6-32 screw terminals. .315″ diameter heater has 8-32 screw terminals. .430″ diameter heater has 10-32 screw terminals.
Type T: Mica Insulator
Mica insulator is the same diameter as the heating element. .260″ diameter heater has 6-32 screw terminals. .315″ diameter heater has 8-32 screw terminals. .430″ diameter heater has 10-32 screw terminals.
Type T7: Ceramic Insulator
Ceramic insulator is the same diameter as the heating element. .260″ diameter heater has 6-32 screw terminals. .315″ diameter heater has 8-32 screw terminals. .430″ diameter heater has 10-32 screw terminals
Type T7: Ceramic Insulator
Ceramic insulator is the same diameter as the heating element. .260″ diameter heater has 6-32 screw terminals. .315″ diameter heater has 8-32 screw terminals. .430″ diameter heater has 10-32 screw terminals
Request Other Electrical Termination
If your filter selections do not return your desired results from our standard configurations, please continue to Refine Results for your specifications. When you are finished, save your selections with the Save Results for Quote button (at the right of this page) and choose Request for Quote for further assistance.
Request Other Electrical Termination
If your filter selections do not return your desired results from our standard configurations, please continue to Refine Results for your specifications. When you are finished, save your selections with the Save Results for Quote button (at the right of this page) and choose Request for Quote for further assistance.
Termination Protection
No options available for this section based on your selections
Type C2: Standard Terminal Box (on flat pad)
Type C2 is an individual terminal box for protecting the terminals on each Cast-In Band Heater half and on many other Cast-In Heater designs with one set of heater terminals. The C2 box design requires a flat pad on half-round castings or a flat surface on other casting designs for mounting. It is made from heavy gauge, rust-resistant sheet metal. The cover is removable for easy access to terminals. The box has two 7/8″ diameter knockouts opposite each other for standard 1/2″ BX connectors.
Type C2: Standard Terminal Box (on flat pad)
Type C2 is an individual terminal box for protecting the terminals on each Cast-In Band Heater half and on many other Cast-In Heater designs with one set of heater terminals. The C2 box design requires a flat pad on half-round castings or a flat surface on other casting designs for mounting. It is made from heavy gauge, rust-resistant sheet metal. The cover is removable for easy access to terminals. The box has two 7/8″ diameter knockouts opposite each other for standard 1/2″ BX connectors.
To simplify installation, Cast-In Heaters fitted with boxes can be factory pre-wired with high temperature lead wire that can be protected with armor cable. If one of these options is required, specify terminal box type, lead wire and cable length.
Satisfies NEMA 1 requirements.
Standard C2 box size: L = 4″ W = 2-1/2″ H = 2-1/8″
Type EP: Explosion & Moisture Resistant Box
Cast iron explosion and moisture resistant boxes should be used in areas where the surrounding air may become contaminated with combustible gases or a high humidity level may exist. Installation requires one box per Cast-In Heater half and they are brazed to the tubular heater. The standard box has one 1/2″ NPT hub.
Type EP: Explosion & Moisture Resistant Box
Cast iron explosion and moisture resistant boxes should be used in areas where the surrounding air may become contaminated with combustible gases or a high humidity level may exist. Installation requires one box per Cast-In Heater half and they are brazed to the tubular heater. The standard box has one 1/2″ NPT hub.
Optional: Two hubs per box available. Cast-In Heater fitted with boxes can be factory prewired with high temperature lead wire, protected with special armor cable. If either of these options is required, please specify the following:
- Number of hubs
- Cable type
- Lead wire length
- Cable length
Type MPR: Moisture Resistant Box
This design has a moisture resistant die cast aluminum box with a non-removable polyurethane gasket in the lid. Lid is secured with captive stainless steel screws. Body and lid are painted in basic industrial gray; interior contains copper ground screw. Box is mounted to a plate that is brazed to the element. Available in a wide variety of sizes.
Type MPR: Moisture Resistant Box
This design has a moisture resistant die cast aluminum box with a non-removable polyurethane gasket in the lid. Lid is secured with captive stainless steel screws. Body and lid are painted in basic industrial gray; interior contains copper ground screw. Box is mounted to a plate that is brazed to the element. Available in a wide variety of sizes.
Request Other Termination Protection
If your filter selections do not return your desired results from our standard configurations, please continue to Refine Results for your specifications. When you are finished, save your selections with the Save Results for Quote button (at the right of this page) and choose Request for Quote for further assistance.
Request Other Termination Protection
If your filter selections do not return your desired results from our standard configurations, please continue to Refine Results for your specifications. When you are finished, save your selections with the Save Results for Quote button (at the right of this page) and choose Request for Quote for further assistance.
Cooling/Flow Tube Fittings
No options available for this section based on your selections
Type FF: Flared Seal Fittings
Brass flared seal fittings are well adapted for low to medium pressure and resistant to mechanical pullout. Available for 3/8″ and 1/2″ diameter tubing with SAE 45° flare.
Type FF: Flared Seal Fittings
Brass flared seal fittings are well adapted for low to medium pressure and resistant to mechanical pullout. Available for 3/8″ and 1/2″ diameter tubing with SAE 45° flare.
| Diameter Tubing |
Thread | Part Number |
|---|---|---|
| 3/8″ | 5/8″-18 | FTG-124-101 |
| 1/2″ | 3/4″-16 | FTG-124-104 |
Scroll for more
Type HS: Hi-Seal Fittings
Hi-seal brass fittings are highly dependable under the most adverse conditions. For reliable and trouble-free service with ease of installation, we strongly recommend hi-seal fittings. Available for 3/8″ and 1/2″ diameter tubing. Male thread is 1/2″ NPT for 1/2″ tube and 3/8″ tube.
Type HS: Hi-Seal Fittings
Hi-seal brass fittings are highly dependable under the most adverse conditions. For reliable and trouble-free service with ease of installation, we strongly recommend hi-seal fittings. Available for 3/8″ and 1/2″ diameter tubing. Male thread is 1/2″ NPT for 1/2″ tube and 3/8″ tube.
| Diameter Tubing |
Part Number |
|---|---|
| 3/8″ | FTG-118-124 |
| 1/2″ | FTG-118-116 |
Scroll for more
Thermocouple Calibration
No options available for this section based on your selections
Type J
United States, Canada, Mexico: Iron/Constantan, Temperature Range: 32-1382°F (0-750°C)
Type J
United States, Canada, Mexico: Iron/Constantan, Temperature Range: 32-1382°F (0-750°C)
Type K
United States, Canada, Mexico: Chromel®/Alumel, Temperature Range: 32-2282°F (0-1250°C)
Type K
United States, Canada, Mexico: Chromel®/Alumel, Temperature Range: 32-2282°F (0-1250°C)
Bayonet Style Thermocouple
No options available for this section based on your selections
Style 1: Spring Adjustable Bayonet Thermocouple
Design Features
Insertion length adjustable from 1″ to 10″. Forms easily to any angle. One style can replace several fixed length thermocouples. Use with bayonet adapters on page 14-87.
Style 1: Spring Adjustable Bayonet Thermocouple
Design Features
Insertion length adjustable from 1″ to 10″. Forms easily to any angle. One style can replace several fixed length thermocouples. Use with bayonet adapters on page 14-87.
Style 2: Armor Cable Adjustable Bayonet Thermocouple
Design Features
Insertion length adjustable over length of armor cable. Forms easily to any angle. One style can replace several fixed length thermocouples. Use with bayonet adapters on page 14-87.
Style 2: Armor Cable Adjustable Bayonet Thermocouple
Design Features
Insertion length adjustable over length of armor cable. Forms easily to any angle. One style can replace several fixed length thermocouples. Use with bayonet adapters on page 14-87.
Thermocouple Terminations
No options available for this section based on your selections
Thermostats
No options available for this section based on your selections
High Limit
General purpose high limit switch with manual reset Once fixed opint is reached, the high limit switch will remain open until the manual reset button is pushed
High Limit
General purpose high limit switch with manual reset Once fixed opint is reached, the high limit switch will remain open until the manual reset button is pushed
SPST
General purpose thermostat recommended for most applications Capable of controlling loads from 120V/30A up to 480V/20A
SPST
General purpose thermostat recommended for most applications Capable of controlling loads from 120V/30A up to 480V/20A
DPST
Recommended for directly controlling high wattage loads due to its heavy duty contacts Capable of controlling loads up to 30 Amps at 277 VAC and 10 Amps at 480 VAC
DPST
Recommended for directly controlling high wattage loads due to its heavy duty contacts Capable of controlling loads up to 30 Amps at 277 VAC and 10 Amps at 480 VAC
Request Other Thermostat
If your filter selections do not return your desired results from our standard configurations, please continue to Refine Results for your specifications. When you are finished, save your selections with the Save Results for Quote button (at the right of this page) and choose Request for Quote for further assistance.
Request Other Thermostat
If your filter selections do not return your desired results from our standard configurations, please continue to Refine Results for your specifications. When you are finished, save your selections with the Save Results for Quote button (at the right of this page) and choose Request for Quote for further assistance.